EICR Testing
Electrical inspection and clear digital reporting.
View serviceElectrical safety and compliance
Fixed-price EICR testing across South London with clear digital reports normally issued within seven days.
Quick answer
An Electrical Installation Condition Report (EICR) is a detailed inspection and test of a property’s fixed electrical installation. It identifies damage, deterioration and safety concerns, records observations using recognised classification codes and gives landlords, homeowners and businesses a clear view of the installation’s condition.
Approved prices
Typical properties with up to 10 circuits. Easy Electrical London Ltd is not VAT registered.
Prices apply to typical domestic properties with up to 10 circuits. Additional circuits, multiple consumer units or unusually complex installations may require a revised quotation. Applicable parking, ULEZ and congestion charges are separate.
01
Testing is carried out methodically across the accessible fixed installation.
02
EICRs are commonly requested by landlords, homeowners, purchasers, sellers, property professionals and businesses. Privately rented homes are generally inspected at least every five years, while owner-occupied homes are commonly recommended for inspection at intervals of up to ten years. The appropriate interval can vary with the property, use and previous findings.
03
Access is needed to the consumer unit and a representative selection of electrical points. Some circuits will be isolated during testing, so there may be short interruptions to power. The duration depends on the size, age, accessibility and complexity of the installation.
04
A satisfactory report means no C1, C2 or FI observations make the report unsatisfactory. C1 identifies immediate danger, C2 identifies potentially dangerous conditions, FI means further investigation is required and C3 is an improvement recommendation.
05
An unsatisfactory result is not the end of the process. We can explain the findings in plain English and, if requested, provide a separate quotation for suitable remedial work. You are paying for a competent inspection and report—not for a guaranteed satisfactory certificate.
06
An unsatisfactory EICR should give you a clear route forward. We review the observations, explain which items need urgent action or further investigation, and prepare a separate quotation for appropriate remedial work. Work proceeds only after approval. Once completed, the affected circuits are tested and the appropriate electrical certification or written confirmation is provided.
07
At a three-bedroom Camberwell flat, testing identified undersized 6 mm² bonding to the gas and water services and exposed single-insulated conductors at several downlight connections. Easy Electrical London installed new 10 mm² bonding, enclosed the affected connections, replaced the consumer unit and retested the installation. An Electrical Installation Certificate was issued and the EICR was updated to a satisfactory outcome.
08
At a three-bedroom Peckham house, an EICR identified a damaged lighting cable that had interrupted CPC continuity and left unwanted voltage on the protective conductor serving several lighting points. A replacement cable was installed using a practical route with ceiling access kept to the minimum reasonably required. Retesting confirmed continuity had been restored and the unwanted voltage removed before a satisfactory EICR was issued.
09
Landlords in England must arrange inspection and testing of rented-property electrical installations by a qualified person at least every five years. Where an EICR requires remedial or further investigative work, it must be completed within 28 days or sooner if the report specifies a shorter period. The report and required confirmations must be supplied in accordance with the applicable regulations.
10
An EICR can help a homeowner understand the condition of an installation, plan maintenance and investigate concerns. Buyers may also arrange an inspection where the age, history or condition of the electrics is uncertain. The report records observations and explains whether further investigation or remedial work is needed.
Helpful information
Most domestic inspections take approximately two to four hours, although larger, older or more complex installations can take longer.
EICR reports are normally issued within seven days.
Some circuits need to be safely isolated during testing, so short interruptions to power should be expected.
We will explain the observations and can provide a separate quotation for appropriate remedial work. There is no obligation to proceed.
No. Your preferred date and time are requests. The appointment is confirmed only when the office contacts you.
Yes. Completed workmanship is covered by a 12-month workmanship guarantee.
Professional. Reliable. Local.
Tell us what you need and we will review the details.